The development of the mold industry is driving the progress of the entire manufacturing industry. Molds will experience wear and tear during use, and the emergence of laser mold welding machines has solved this problem. It has delayed the life of molds for many years, which is a considerable expense for enterprises. So the mold laser welding machine has been recognized and favored. Today, the editor will introduce how to adjust the microscope parameters of the mold laser welding machine?
Mold laser welding machine is a fine classification of laser welding machines, also known as mold laser repair welding machine. Its main principle is to use high-energy laser pulses to perform laser spot welding, laser repair welding and other methods on materials to locally heat small areas. This is a new type of precision laser welding method. Therefore, the adjustment of the microscope has a significant impact on the welding effect. How to adjust the microscope to achieve the best effect when operating the mold laser welding machine?
Microscope is crucial for mold laser welding machines. The environment is relatively complex, and unclear or untimely viewing will inevitably affect the welding effect. So how to adjust and use it? The Jixiangyun Laser Equipment editor recommends the following methods and adjustment techniques to everyone.
1. Before the laser welding operation, turn the clear control knob on the outside of the eyepiece barrel of the microscope clockwise to the bottom, so that the two eyepiece barrels are at the same height. The purpose is to maintain consistent clarity between the two glasses when observing the workpiece.
2. Place the workpiece on the workbench during operation, move the workbench up and down, and observe the workpiece in the microscope to make it in the best clear state in the field of view of the microscope. When laser welding any workpiece, the workpiece must be in a clear state. Firstly, clarity is used to ensure that it conforms to the focal length height. Secondly, the process of laser welding can be clearly seen by the eyes to ensure that the welding quality is okay.
3. When laser welding, it is strongly required that customers observe the workpiece with two eyes simultaneously while using a microscope. The eyes should not be tightly attached to the sight glass, nor should they be far away from the sight glass. It is best to maintain a distance of about 5 to 10 millimeters. When the lines of sight cannot overlap, the two eyepiece holders of the microscope can be adjusted to create a three-dimensional effect on the workpiece we see. Being able to see the high and low positions on the workpiece, especially the small positions of precision parts, can be clearly seen. And the repaired workpiece can be inspected to observe whether the repaired welding position has undercutting or burning damage, to ensure that the repaired welding position and height meet the requirements.
Mold laser welding machine and repair machine repair and weld cracks, broken corners, touched edges, and damaged sealing edges of hard materials such as molds, precision injection molding, die-casting, stamping, stainless steel, etc. at a temperature of 50-60 Rockwell; High accuracy, laser welding spot diameter is only 0.2mm~1.5mm; The heated area is small, and the processed parts will not deform; After welding, it can corrode without affecting the effect.